The Down Strings page identifies strings in the plant that are inoperative over the selected time range. The energy loss due to the inoperative strings is also estimated and quantified, considering inverter downtime and curtailment states.

For example, if a significant number of strings are down on an inverter, but the inverter is suffering downtime due to grid curtailment, the additional energy loss due to the down strings remains zero since fixing the strings would not produce more energy at the inverter AC output.


DC Health - Down String - Summary

The summary KPIs give a quick overview of the actual, revenue and recoverable losses due to down strings. In addition, the total number of down DC inputs is displayed.


Down String Losses per inverter


The Strings Down by Inverter graph shows each inverter's energy losses and the average of all inverters.ç


Plant-Level Losses due to Down DC Inputs

The Plant-level Losses due to Down Strings graph shows the plant losses by day due to down strings over the selected time range. The bars indicate the number of strings, and the line indicates the loss in kilowatt-hours.